Quality Control True Precision. PTW. Quality Control Connect ... } C E marked, class IIb certified diagnostic dosimetry system, fully compliant with IEC 61674 for acceptance testing and quality control measurements on RAD, FLU, DENT, CT and MAM X-ray units } A llows to connect either a semi-conductor detector (R/F/D or MAM), CT ionization chamber (100 mm or 300 mm long) or a shadow-free ionization chamber (6 cm³ or 75 cm³) for no interferences with the AEC } C ombined with the NOMEX® multimeter, a single exposure simultaneously captures dose, dose rate, dose per pulse, pulses, frequency, irradiation time, tube voltage, total filtration, half value layer and waveforms for both kV and dose rate } Provides for automatic air density correction CT Ionization Chamber,100 mm NOMEX® Multimeter R/F/D Diagnostic Detector Shadow-Free Ionization Chamber, 6 cm³ } Stores the last measurements and allows data and waveform export as XLS, XML or CSV file via USB or Bluetooth® } S oftware menu available in different languages (Chinese, English, French, German, Italian, Japanese, Portuguese, Russian, Spanish) H e a lt h p h y s i c s nuclear medicine diagnostic radiology r a d i at i o n t h e r a p y Technical Data Standard Measuring ranges Current Resolution Charge Resolution Irradiation time Pulse Pulse width Frequency Temperature Relative air humidity Air pressure IEC 61674, DIN EN 61010-1, IEC 61326-1 2 pA … 20 µA, < 2% 20 fA 2 pC … 200 mC, < 2% 4 fC 1 ms … 9999 s, ± 1 ms (0 … 9999), ± 1 pulse (0.1 … 500) ms (0.2 … 500) Hz (10 … 40) °C (10 … 80) %, max. 20 g/cm³ (700 … 1060) hPa The respective measuring range depends on the detector connected, e.g. PTW R/F/D detector, MAM detector and CT ionization chamber: Air kerma rate R/F/D 50 nGy/s … 500 mGy/s Air kerma R/F/D 50 nGy … 5 kGy Resolution 0.5 nGy/s Air kerma rate MAM 130 nGy/s … 1.3 Gy/s Air kerma MAM 130 nGy … 13 kGy Resolution 1 nGy Air kerma rate CT 150 µGcm/s … 1.5 kGycm/s Air kerma CT 150 µGcm … 15 MGycm Resolution 1.5 µGcm/s Energy dependence ≤±5% PC interface Outer dimensions Weight Bluetooth® 2.0, USB 2.0 Full-Speed 160 mm x 150 mm x 40 mm 550 g, incl. batteries Ordering information [L981816] NOMEX® dosemeter measures dose, dose rate, dose/pulse, pulses, time, kV, TF and HVL depending on the detector connected. NOMEX® multimeter, semiconductor detectors or ionization chambers can be connected. Includes software and a transport case. [L981814] NOMEX® set for measurements in R/F/DENT/CT/MAM. Includes NOMEX® dosemeter, NOMEX® multimeter, NOMEX® software, USB cable (2 m, 5 m), transport case. Measures dose, dose rate, dose/pulse, pulses, time, kV, TF, HVL. External semiconductor detectors or ionization chambers can be connected. ©PTW. All Rights Reserved. D909.139.01/00. Effective 2013/02. Previous specifications are void. www.ptwnomex.com USA | Latin America | China | Asia Pacific | india | UK | France | Iberia | germany Knowing what responsibility means