Transcript BlueFormat
HORIBA Portable Meter Line-up pH ○ ○ ORP Conductivity ISE ○ ○ ○ Salinity Temperature ○ Depth TDS SSG ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Turbidity ○ ○ ○ DO (O2) Resistivity ○ ○ ○ ○ ○ ○ ○ ○ ○ HORIBA Benchtop Meter Line-up pH ○ ○ ○ ○ ○ ○ mV ○ ○ ○ ○ ○ ○ ○ ○ ○ Conductivity ○ ○ Resistivity ○ ○ ○ ○ Salinity ○ ○ ○ ○ ○ ISE Temperature Navi function ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ HORIBA Pocket Meters TWIN Series (pH, Conductivity) Pocket-size HORIBA flat sensor meter. TWIN pH meter is waterproof, suitable for lab and field use. Replaceable sensor. pH Conductivity Cardy Series (Salt, NO3-, K+, Na+) HORIBA flat sensor technology is available in pocket-size. World’s only pocket-size Ion meter for lab, agriculture, food, environmental study, etc. Sensor replaceable. Ion HORIBA Portable Meters OM series (OM-51-2/-10/-lab) Portable single parameter meter to measure Dissolved Oxygen. No optional unit necessary for RS-232C, AC or printer connection. Compact design, larger LCD with IP67 rated waterproof realizes easy use in the field Data storage up to 300 sets with time stamp. DO O2 Temperature ES-50 series (ES-51) Portable single parameter meter to measure Conductivity. No optional unit necessary for RS-232C, AC or printer connection. Compact design, larger LCD with IP67 rated waterproof realizes easy use in the field Data storage up to 300 sets with time stamp. Conductivity Resistivity Salinity Temperature D-50 series (D-51,52,53,54,55) Portable Multi-Parameter meter to simultaneously measure pH and ORP/Ion/Conductivity/DO. No optional unit necessary for RS-232C, AC or printer connection. Compact design, larger LCD with IP67 rated waterproof realizes easy use in the field Data storage up to 300 sets with time stamp. pH ORP Ion Conductivity DO Temperature U-20 series (U-22, W-22/23) Portable Multi-Parameter meter to simultaneously measure up to 13 water quality parameters. Cable length up to 100 m with waterproof rating of IP67 One-touch calibration makes work easy Up to one month monitoring Heavy-duty probe fits into 2-inch well. (flowcell option available) Expandability to printer, RS-232 and GPS unit pH ORP Salinity Ion Conductivity (select 3 from 6 options) Turbidity TDS Seawater Specific Gravity DO Temperature Depth Benchtop Meters DS-50 series (DS-51, DS-52) Benchtop single parameter meter to measure Conductivity RS-232C output standard Battery operation possible for portability. D-52 with color display and navigation features Conductivity Resistivity Salinity Temperature F-50 series (F-51BW, 52, 53, 54, 54BW, 55) Extended GLP/GMP compliance with World’s First meter to comply 21CFR Part11 requirements. World’s First benchtop meter with color LCD display World’s First meter with Compact Flash interface. User friendly navigation features full of HORIBA’s 50 years experience Meter checker available to verify meter performance RS-232C output standard for all models. Battery operation possible for portability. pH ORP Ion Resistivity Temperature Conductivity Salinity HORIBA Sensor Technology New ToupH Series Electrode 1995 HORIBA Introduced ToupH 9610-10D electrode 2003 HORIBA Introduces ToupH family with… Ag+ Trap Technology No Ag+ spill, long lasting ToupHer Design Shorter and wider Ag+ Trap Technology No Ag+ spill, long lasting Ag+ within the internal solution saturates and clogs the liquid junction Slow Response Ag+ Contaminates sample Ion exchange material traps Ag+ and prevents Ag+ from spilling into the internal solution Maintained Fast Response No Ag+ Contamination New Former KCl Internal Solution Pin hole to Teflon Coating Ag/AgCl Electrode KCl Internal Solution Pin hole to Teflon Coating Liquid Junction Ag/AgCl Electrode Ion exchange material Liquid Junction Ag+ Trap Technology 3 months monitoring in Protein Sample Conventional Repeatability New Initial 3 months Initial 3 months pH4 0.02 0.01 0.01 0 pH7 0.03 0.03 0.02 0 pH9 0.02 0.11 0.01 0.04 Sensitivity (%) pH4 to pH9 99 86 99 98 Tap Water T90 14 327 11 32 Liquid Junction Color White Black White White Ag+ Trap Technology 3 months monitoring in Tap Water The response is 40 times faster 10 mV 5 0 Conventional -5 New -10 0 300 600 900 time(s) 1200 1500 1800 ToupHer Design Shorter and Wider New Conventional 11mm 15mm φ6mm φ8mm Strength increased by 4.4 times more than former ToupH electrode. Doesn’t break from 1m height. Now stronger against impact from all sides Requires less sample volume Available as ToupH Family: General purpose, Sleeve and Micro pH electrodes Electrode Comparison HORIBA vs. Accumet (13-620-285) HORIBA Accumet HORIBA Fisher Internal solution Reference Ion trap Internal solution Reference Ion trap KCL Ag/AgCl Yes KCL Ag/AgCl No ToupH Design No specific design for durability G pole and R pole are on the same height G pole and R pole are on a different height Response Due to no solution made for Ag+ spill, the response time will become slow in a few months. Strength Not a durable design, breaks from 10cm height. Temperature accuracy for pH measurement Temperature detected at G pole and the actual temperature at R pole may differ →unreliable pH value Electrode Comparison HORIBA vs. Mettler HORIBA Mettler HORIBA Mettler Internal solution Reference Ion trap Internal solution Reference Ion trap KCL Ag/AgCl Yes KCL Ag/AgCl Yes ToupH Design Durable Design Humidity secured with the sealed cap Soaked in KCl filled cap 8 HORIBA Stabilizes in 3 minutes 7 pH Response Due to the storage in KCl solution, response against tap water is very slow. 7.5 METTLER 6.5 6 Stabilizes in 9 minutes M ETTLER 410 W TW S enTix61 H O R 9611 5.5 5 0 300 tim e(s) 600 900 *Stabilization: Within 0.01pH drift in 1 minute Electrode Comparison HORIBA vs. ORION (8202, 8272) HORIBA ORION HORIBA ORION Internal solution Reference Ion trap Internal solution Reference Ion trap KCL Ag/AgCl Yes KI Pt No ToupH Design No specific design for durability Stable temperature readings No temperature sensor 8 7.5 Initial 40℃ 2 days 7 pH Strength Not a durable design, breaks from a certain height. HOR9611 ORION8202 ORION8272 6.5 Room temp. 1 hour Stability pH value drifted by 0.5 pH when applied temperature drift test. Room Temp. 1 hour 6 5.5 5 0.5pH Electrode Comparison Summary HORIBA #9611 #9610 (new) (old) TOADKK GST- 5731C METTLER InLab 410 InLab 413 Feature ToupH Reference Silver electrode ion trap 8202 ROSS Strong・pH Glass ToupH electrode ORION 8272 WTW FISHER 13-620SenTix61 Sentix20 285 ROSS/ Accumet Sure-Flow standard Strong・ Superior durability pH Superior durability Filter Silver ion trap Solid polymeric electrolyte Platinum electrode Filling solution saturated with Ag Gel Tap water response (after three months) ◎ × ◎ × × ○ ◎ × × × Durability ◎ ○ ○ ◎ × △ △ × ◎ × Ranking No.1 No.7 No.2 No.3 No.8 No.5 No.3 No.8 No.5 No.8 Micro ToupH (9669-10D) World’s smallest w/temp. sensor 1. No sample contamination In the past… Ag+ Trap Technology Internal solution ooze out from Liquid junction, contaminating the sample No contamination! 2. Unbreakable In the past… Electrode hit stirrer or beaker and broke ToupH Design Strength even breaking the beaker! 3. High Precision In the past… Calibration in room temperature →measurement at 37℃ pH0.1 error against pH4 solution Built-in Temperature Sensor Reliable measurement! 4. For microvolume or Precious samples In the past… Enough volume of precious or large container has to be prepared 3mm diameter sensor Requires only 0.3ml of your sample ToupH Sleeve (9677-10D) Ideal for viscous or slurry sample 1. No sample contamination In the past… Ag+ Trap Technology Internal solution ooze out from Liquid junction, contaminating the sample No contamination! 2. Unbreakable In the past… Electrode hit stirrer or beaker and broke ToupH Design Strength even breaking the beaker! 3. Works with difficult samples In the past… Hard to measure viscous sample (does not come in contact with liquid junction) or slurry sample (clogs the liquid junction) Slurry Design Viscous sample still contacts with liquid junction, cleaning is also easy ISFET Electrode (0030-10D) Ideal for food measurement 1. Easy maintenance ・No need to replace or refill KCl internal solution ・Just replace a tip when sensor is consumed Easy to use 2. Ideal for food measurement ・Food additives (CMC, Glycerine, KCl) is used for internal solution ・Glass will not break into sample (food) ・Tip design allows for easy sample entry For meat and fruit 3. Minimize running cost ・Replaceable tip makes it economical and environmentally friendly. Just replace the tip! Optional Products Cleaning Reagent 10% Thiourea, 1% HCl Model #220 Effective for liquid junction cleaning, removing contamination from inorganic sample Over 50% of electrodes recovers, based on HORIBA experience. Digital Simulator Digital Simulator Model X-51 Model X-52 Checks meter performance Gives simulation signal to the meter (for pH, mV, Ion, DO check ) Checks meter performance Gives simulation signal to the meter (for Conductivity check ) Electrode Stand AC Adatper Ink Printer For Portable meters For Portable meters For GLP/GMP compliance