Transcript Document
Enviritech Engineering Ltd Unit 6, Enterprise & Research Centre, Institute of Technology Carlow, Kilkenny Road, Co. Carlow Objective • Enviritech Engineering is intent on providing alternative energy systems at an affordable price. • We offer assistance to the installer in the design, sales and technical backup requirements as well as providing reliable quality products. • Our approach is a holistic one and we aim to meet the specific requirements of the client, rather than just offering our product range. Customer Requirements Quality Value Customer Satisfaction Service • The quality of the products is very high. We have vetted many systems and realize that the product quality is key to success. • The product is produced with limited overheads and priced accordingly. They offer excellent value for money. • We train all our installers to provide a quality service. Meeting the Needs Efficient • High Efficiency. • Robust construction and reliability. • Low cost. • Providing simple and effective controls can ensure optimal operation. • Systems shall be adaptive to suit a wide range of applications Reliable Affordable Controlable adaptable Heat Pump • The heat pump consists of Copeland scroll compressors and stainless steel plate heat exchangers matching the market leaders. • The refrigerant is R417a which is a non ozone depleting gas, pre charged at the factory. • Each heat pump is provided with a filter for the primary and secondary loop. • A remote (wire) controller is also provided which can allow the heat pump be controlled from within the home. Water to water. • This is a very cost effective way of heating, its efficiency is comparable with a direct expansion system. Without the need to charge the system with refrigerant or the worry of migrating lubricants. • It is very reliable as it employs Copeland scroll compressors. The heat exchangers are stainless steel and 50% over sized that of our competitors. Which enables them to withstand poorer water quality for longer. • The units are priced from €4500 making them the most competitive unit on the market. • The control is derived from standard oil boiler controls which are readily understood and easily incorporated into existing systems. • They can be used in many applications such as combined systems with solid fuel and radiators. How it works • For every one kilowatt of electrical energy, the heat pump takes over 4 kilowatts of heat energy from the source. • It adds these energies together and inputs them into the house at a useful temperature. • Thus making it over 500% efficient. No water ! No problem ! Frequently asked questions • • • • • • • • • • • • • How long is the pay back period? Depending on application 1.5 to 4 years subject to grant approval. How much to drill a well? Well costs typically between €1300 and €3000. Can I use an existing well? Yes, provided adequate and suitable water supply. Can one well supply both the heat pump and domestic water? Yes How much water will be required? 0.5 –0.75 l/s (400 to 600 gallon/hr) What is a heat pumps expected life? 20 years What warranty is provided? 2 years, additional warranty is available Can solar panels be used also? yes they complement the system What temperature will my hot water be? 55˚C or above Can it heat radiators? Yes Although not as efficient as under floor heating, for best results Radiators should be 30% over sized Can it be used to supplement an existing system? Yes. Due to lower insulation in existing buildings, we recommend retaining the existing system for the colder days. What if I require more heat than the product can offer? Special order units are available in multiples of the standard range and also for outdoor applications. Can I reuse the water after the heat pump? Yes, but not recommended for human consumption. Test results Tests carried out at TNO accredited laboratories Holland show COP over 5 (efficiencies in excess of 500%) Cost Benefits • These are the most competitive heat pumps on the market. Model Power Output KW House size (sq ft). Price (ex vat&del) SEI No. LSQ03RW Single Phase 10 2150-3600 € 4,500 SEI-HP-274 LSQ04RW Single Phase 13 2800-4660 € 5,000 SEI-HP-275 LSQ05RW Three Phase 17 3655-6100 € 5,500 SEI-HP-276 • 30% deposit is payable on all orders. • Standard terms and conditions apply. Advantages 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. Small ground area required. Very efficient over 500%. Copeland Scroll compressors ensure high efficiency and reliability. Long life expectancy in excess of 20 years. Can avail of cheaper night rate electricity. Can be used for heat recovery. Simple controls, easy to use and integrate into other systems. Existing rivers, streams, wells and lakes can be employed instead of bored wells. Bore holes are not as expensive as direct expansion bore hole applications or ground collectors. (normally in the region of €1,300 to €3,000). Environmentally friendly employing non ozone depleting refrigerant R417a. Can be used as a stand alone or complimentary to existing heating system. Lower capital & installation costs than many other systems. Oversized heat exchangers prolong service intervals and reduce pump power required. Units are factory charged so there is no requirement for a refrigerant Engineer. The units are scaleable to provide any heating or cooling demand required. 16 14 12 10 8 6 4 2 0 night day bulk W/W B/W Hp Hp Cents/KWH A/W wood Hp pel nat gas oil lpg Based on SEI fuel comparison GRANT APPLICATION W/W heat pump Solar Panels €4300 €300/sq meter We can assist you with the application Contact Us on 059 9176261 or [email protected] Other Products and Services • • • • • Underfloor heating systems. Heating control systems. Solar Panels. Wind turbines. Bespoke alternative and conservative energy systems • Energy Auditing and Energy labelling. • Consultation and Design. Underfloor heating • Enviritech Engineering can design and supply full under floor heating systems. Including Pex pipe , manifolds and full system controls. • Our system is contra flow, which allows floors to heat uniformly preventing cold spots occurring. It is also designed to increase the efficiency of the heating system. • Simply send us the floor plan of the building and we can size the floor loops, pressure drops and required flow rates. Enviritech Engineering Heating calculator. Room Kitchen living room hall sitting room office landing bedroom 1 bedroom 2 bedroom 3 bedroom 4 bedroom 5 Utility Sunroom Bathroom 1 Total Requires Value in meters to be entered Requires Value of 1 for yes or blank for no. Copy Right protected Floor Length width Floor distance to zone Ports zone Ports zone Ports RAD No of loop (M) (M) Area Manifold 1 2 3 Watts loops 1 7.4 4.28 31.7 4 1 2 0 0 0 2 1 4.8 5.33 25.6 2 1 2 0 0 0 2 1 5.325 2.5 13.3 1 1 1 0 0 0 1 1 5.4 4.8 25.9 3.5 1 2 0 0 0 2 1 4.163 4.8 20 4 1 2 0 0 0 2 1 7.3 2.5 18.3 3 0 1 1 0 0 1 1 4.799 3.3 15.8 3.5 0 1 1 0 0 1 1 3 4.5 13.5 7 0 1 1 0 0 1 1 3.5 4.8 16.8 4 0 1 1 0 0 1 1 5.026 4.8 24.1 1.5 0 1 2 0 0 2 1 7.8 4.45 34.7 1 0 1 2 0 0 2 1 3 3.8 11.4 6 1 1 0 0 0 1 1 3 4.95 14.9 5.5 1 1 0 0 0 1 1 2.6 4.8 12.5 1 0 1 1 0 0 1 14 278 11 9 0 . . flow Pipe Loop M of Stapels l/min length length Track 2.04 188 93.8 21.1 64 1.64 147 73.3 16.5 50 1.71 74.2 74.2 8.34 26 1.67 155 77.3 17.4 53 1.28 124 62.2 14 42 2.35 105 105 11.8 36 2.04 92.8 92.8 10.4 32 1.74 87.2 87.2 9.81 30 2.16 99.1 99.1 11.1 34 1.55 137 68.4 15.4 47 2.23 192 96.1 21.6 65 1.47 73.8 73.8 8.3 25 1.91 91.5 91.5 10.3 31 1.6 69.7 69.7 7.84 24 35.8 1635 184 559 Rads over sized for heat pump application Heat Pump Insulation Factor size . KW 0 House Old with little/no insulation Recent build insulated cavity wall Very well insulated Insulation Factor 3 2 1 Wind turbines No two applications are the same. • If you wish to reduce your electrical costs you may consider a wind turbine. • We can offer battery backed, stand alone or grid tied systems. • Contact us to find out what is your best option. UE 6 UE 15 UE 33 UE 42 650W 1500W 3300W 4200W 10.5 / 25 10.5 / 25 10.5 / 25 11.5 / 27 PEAK OUTPUT 750W 1750W 3650W 4500W CUT IN m/s / mph 2.7 / 6 2.7/ 6 2.7 / 6 2.7 / 6 10 / 600 / 720 10 / 600 / 720 16 / 375 / 450 16 / 375 / 450 68 kWh (18%) 178 kWh (18%) 352 kWh (18%) 412 kWh (16%) 115 kWh (25%) 278 kWh (25%) 568 kWh (25%) 685 kWh (24%) 2.20m / 7 ft 3.20m / 11 ft 4.05m / 13 ft 4.90m / 16.2 ft 3 2/3 3 Carbon Fiber composite Carbon Fiber composite Carbon Fiber composite Carbon Fiber composite SWEPT AREA Sq.m/ sq.feet 3.7 / 43 9.2 / 95 16.4 / 175 19 / 205 LATERAL THRUST 340 nts. 800 nts 1200 nts 1490 nts. Tilt Angle Angle Angle 27mph 27mph 27mph 27mph Electro- dynamic Switch Electro- dynamic Switch Electro- dynamic Switch Electro-dynamic Switch UNIT WEIGHT 21 Kg 34 Kg 77 Kg. 89 Kg GENERATOR PM 3 Phase alternator PM 3 phase alternator PM 3 phase alternator PM 3 phase alternator 12/ 24 / 36 / 48 12 - 240 HV/LV 12 - 240 HV/LV 24 - 240 HV/LV Incl. but separate Incl. but separate Incl. but separate Incl. but separate WARRANTY 2 yrs. 2 yrs. 2 yrs. 2 yrs. OPERATING LIFE 20 yrs. 20 yrs. 20 yrs. 20 yrs. SURVIVAL WIND RATED OUTPUT RATED WIND SPEED m/s/mph POLES /RPM - 50hz/ - 60hz Monthly KWH 10mph / 4.5 m/s PLF % Monthly KWH 12mph / 5.4 m/s PLF % ROTOR DIAMETER NUMBER OF BLADES BLADE MATERIAL GOVERNOR GOVERN SPEED GOV. SHUT-DOWN / OPTIONAL STOP VOLTAGES AVAILABLE ELECTRONIC CONTROLLER 3 55 m/s 125mph 55 m/s125mph 55 m/s 125mph 55 m/s 125mph MFR. SUG. ROUTINE MAINTENANCE Annual inspection Annual inspection Annual inspection Annual inspection Price (Ex Vat & delivery) €1795 €3290 €6850 €7680 Energy Auditing / Rating We can offer the following services • • • • • • • Building Energy Rating assessments Pre planning design consultations Rating improvement of existing buildings. Design and fit. Energy meter validation Energy Survey of process and procedure methods. Power Factor correction. Optimisation of energy and billing tariffs. For further Enquiries: Contact our offices Unit 6, Enterprise & Research Centre Institute of Technology Carlow Kilkenny Road Co. Carlow Ph: 059 91 76261 Fax: 059 91 76372 E-mail: [email protected]