Transcript Slide 1
Yatindra/ Sanjay Prepared Quality Bulletin Naresh Pant SKD Naresh Pant App Horizontal deployment Running model New model Re-FPA New part approval S/No. Product Model Claim section Claim date Date of imp KAS/CE/ 12/01 CTV/ LCD All CTV/ LCD Field/ Ware House Year 2011-2012 22.6.2012 Quality issue Cause Implemented serial No Analysis • Moisture related defect in market . • To avoid water inside the set in carton box in warehouse. • Set can be out side of Poly bag in carton box due to not use tape on poly bag. Why? To Reduce moisture related defect. Why? To avoid water inside the set. Why? To reduce component rejection in field. Start Date Model VPC14NM -CYK SPZ14NG -CZK 22.06.1 VPJ21UM-DZK 2 LCDTVVAA32HMQMK LCDTVSAP22HHQMK Before QA System Improved QA System • No Side tape around carton box top & below • Side tape around carton box top & below side 100% & No taping on poly bag . implementation. & tape used on poly bag . Start Serial No 21061290010 1009824 21061290020 2613693 21061290010 5804645 21061211011 1403534 21061211020 3400910 References PATD / ICTS / Test Std. / IG control no. ECN No. JIR control no. Others ( Refer test Report of PATD. & BOm change )