Transcript RayCAm
Starting with infrared thermography PC_F Physics Line - 1 Personnel et confidentiel Thermography interests • To save on the invoices of electricity by improving the output of the electric installations • To locate the energy losses • To avoid the stops of production, machine breakings • To eliminate the fire hazards • To decrease the insurance premium PC_F Physics Line - 2 Personnel et confidentiel Why thermography is it so useful ? 3 essential advantages: •Non-contact measurement •Method with two dimensions •Real time method PC_F Physics Line - 3 Personnel et confidentiel Why use thermography? •Better safe than sorry That should be our motto! •Infrared thermography: a powerful diagnostic tool for preventive maintenance Enables corrective action to be taken prior to costly breakdowns PC_F Physics Line - 4 Personnel et confidentiel Thermography application •Electrical maintenance •Mechanical maintenance •Building thermics •Industrialisation/manufacturing •Research and Development PC_F Physics Line - 5 Personnel et confidentiel Electrical maintenance PC_F Physics Line - 6 Personnel et confidentiel Thermography applications •Main use: electrical maintenance •Objective: Classification of faults in order of seriousness Necessary to assess •Recommandations PC_F Physics Line - 7 Personnel et confidentiel Electrical maintenance •Aim: highlight, in loaded electrical infrastructures, overheating due to: Poor connections Overloads Phase unbalance Faulty contacts …. PC_F Physics Line - 8 Personnel et confidentiel Material deterioration Production stoppages Operating losses Fires …. Electrical maintenance •Role of the camera: Provide decisive elements enabling: Identification of work to be undertaken Facilitate maintenance, save time and increase safety PC_F Physics Line - 9 Personnel et confidentiel Electrical maintenance •Methodology Scanning of the entire electrical installation when the elements are in normal load Spatially located anomalies, possible calculation of overheating Definition of extent of emergency and management of anomalies PC_F Physics Line - 10 Personnel et confidentiel Electrical maintenance BT/TBT electricity Faulty connection PC_F Physics Line - 11 Personnel et confidentiel Faulty fuse contact Electrical maintenance BT/TBT electricity Faulty connection Fuse holder connection PC_F Physics Line - 12 Personnel et confidentiel Cable head Electrical maintenance BT/TBT electricity Incorrect connection screwdown PC_F Physics Line - 13 Personnel et confidentiel CA 6250 : Micro-ohmmeter 10A measure of continuity of the masses measure of state of surface and plating, measure of the quality of the contacts (switches, relay), measure of the resistance and the resistivity of cables, check of good mechanical connections, measure of the resistance of the windings and\or the warm-up of motors and transformers, ...everywhere it is necessary to control the quality of the connections, the contacts and the surfaces. PC_F Physics Line - 14 Personnel et confidentiel Electrical maintenance BT/TBT electricity Wrongly calibrated fuse PC_F Physics Line - 15 Personnel et confidentiel CA 6115 : Electrical installations tester PC_F Physics Line - 16 Personnel et confidentiel Electrical maintenance BT/TBT electricity Unbalanced load PC_F Physics Line - 17 Personnel et confidentiel Power & Harmonics measurement CA 8230 Série F0X F09 Clamp Power measurement Active Reactive Apparent TRMS PC_F Physics Line - 18 Personnel et confidentiel Power & Energy Active Reactive Apparent Harmonics single / Balanced three-phase CA 8334 Power & Energy Harmonics single / three-phase Recordings Transient captures Trigerring on alarms… Electrical maintenance HTA/HTB electricity Inspection of high voltage lines PC_F Physics Line - 19 Personnel et confidentiel Contact problem with selector Electrical maintenance HTA/HTB electricity Insulator support to be tested PC_F Physics Line - 20 Personnel et confidentiel Faulty insulator Electrical maintenance HTA/HTB electricity Overheating on insulator connection PC_F Physics Line - 21 Personnel et confidentiel Faulty connection on high voltage connection Mechanical maintenance PC_F Physics Line - 22 Personnel et confidentiel Mechanical maintenance •Because of friction, mechanical parts heat normally •Aim of thermography: highlight abnormal heating Replace parts in time PC_F Physics Line - 23 Personnel et confidentiel Mechanical maintenance Testing of mechanical heating Faulty rotation PC_F Physics Line - 24 Personnel et confidentiel Mechanical maintenance Engine heating PC_F Physics Line - 25 Personnel et confidentiel Mechanical maintenance Unbalanced thresholds PC_F Physics Line - 26 Personnel et confidentiel Ventilator Canalisation and insulation Blockage in a canalisation PC_F Physics Line - 27 Personnel et confidentiel Leaking valve Canalisation and insulation Condition of thermal insulation to be inspected PC_F Physics Line - 28 Personnel et confidentiel Deterioration of thermal insulation INDUSTRIALISATION / MANUFACTURING: Testing of instruments at end of chain, fast general checking, rejection of non-compliant assembly Endurance tests on « heating table », detection on-the-spot and over time of proper functioning of parts Endurance tests on « vibrating table », detection of faulty contacts, faulty joints, etc. Testing of industrial processes Paper industry PC_F Physics Line - 29 Personnel et confidentiel Industry: +120 °C to +900 °C With high temperature filters (optional) Research/development • Scientists researching new methods for solving problems • Thermocouples: - Have to be in contact with the component measured - Effect on the results • Thermography: • Non-destructive analysis capacity • Detects very low differences in temperature, highlights thermal exchange phenomena • No contact method, highlights the problem PC_F Physics Line - 30 Personnel et confidentiel Research/development Quality control during final phase of development Protection against short-circuits Heating of complex processors on printed circuits PC_F Physics Line - 31 Personnel et confidentiel Heating at the base of a component OX7104 Portable oscilloscope 4 isolated channels Voltage, current, temperature measurement Recordings, Harmonics 12-bit converter Colour touch screen with graphic commands Ethernet communication MTX 3283 Multimeter Large display with up to 4x 100,000 counts V/A automatic selection via leads connection Recording and graphic processing up to 6,500 measurements Communication : Bluetooth or RS232 or USB PC_F Physics Line - 32 Personnel et confidentiel Research/Development • Instruments for the general public Accelerate market launch Prior to production, comprehensive tests Ascertain usable power and the manner in which it is dissipated PC_F Physics Line - 33 Personnel et confidentiel Research/Development • Automotive sector Solutions for thermal protection of engines Products for monitoring temperature beneath the chassis Instantly observe critical zones PC_F Physics Line - 34 Personnel et confidentiel ResearchDevelopment • Pharmaceutical industry Observation of variations in temperature during chemical reaction, study on microplates PC_F Physics Line - 35 Personnel et confidentiel Research/development • Food industry Development of new cooking/freezing techniques (techniques can be dangerous for public health) PC_F Physics Line - 36 Personnel et confidentiel Infrared Thermographic Camera Marie COURRIERE Marketing / Product Manager PC_F Physics Line - 37 Personnel et confidentiel Optimal ergonomy for simplified use Easy to handle : Reach all the functions with only one hand thanks to its form like a gun Access to the dropdown menu Access to the laser aiming PC_F Physics Line - 38 Personnel et confidentiel Optimal ergonomy for simplified use Moveable screen: Direct the screen according to your positioning with respect to the target Closed, the LCD screen is protected PC_F Physics Line - 39 Personnel et confidentiel Keyboard presentation PC_F Physics Line - 40 Personnel et confidentiel RayCAm: the solution in all your measurement conditions Uninterrupted measurements Use of the tripod Too strong luminosity Use of the sun-shield More than 4 hours of uninterrupted inspection 2 batteries delivered Adapted to many industrial conditions Protection IP 54 RayCAm is delivered with all its accessories in a bag PC_F Physics Line - 41 Personnel et confidentiel RayCAm: the solution at your sight Many pallets available PC_F Physics Line - 42 Personnel et confidentiel RayCAm, save time Inspect in a few seconds… Automatic recognition of the hottest point… PC_F Physics Line - 43 Personnel et confidentiel RayCAm, save time … and isolate the significant zones: function alarms/isothermal PC_F Physics Line - 44 Personnel et confidentiel RayCAm, the + •A wonderfull memory 1000 radiometric picture recordable •Near to the target Measurements from 10 cm •Precision and simplicity Target, point and measure with the laser aiming PC_F Physics Line - 45 Personnel et confidentiel RayCAm, righter measurements Possibility of parameterizing directly in RayCAm all the characteristics influencing measurement Emiss: Distance: Temp Amb: Humidité: PC_F Physics Line - 46 Personnel et confidentiel 0.95 5m 25.5°C 25.2 °C 50 % RayCAm, measurements are posted in real time All information necessary to your analysis present on your screen Spot temperature Scale of the thermogram: a temperature associated with a color Operational condition PC_F Physics Line - 47 Personnel et confidentiel Emissivity Load state Time Communication, power supply Electric cable USB cable Video cable PC_F Physics Line - 48 Personnel et confidentiel RayCAm range Performances of the picture RayCAm C.A 1885 Detector RayCAm C.A 1883 RayCAm C.A 1880 UFPA microbolometer / Matrix 160 x 120 Detection frequency Detection à 50 Hz Dtection 9Hz 8 to 14 μm Spectral band Field of sight Min. Foc. NETD RayCAm C.A 1881 Dist. 20° x 15° 10 cm 0,1 °C 38° x 28° 1 cm 0,12 °C 20° x 15° 10 cm Screen TFT 2,5’’ color, multi-palette Picture Live, hold, opening, erasure, 1000 pictures recordable PC_F Physics Line - 49 Personnel et confidentiel RayCAm offer Measurements RayCAm C.A 1885 Temperature range Optional range Precision Measurements correction Use temperature Storage Relative Humidity Configuration PC_F Physics Line - 50 Personnel et confidentiel RayCAm C.A 1883 RayCAm C.A 1881 RayCAm C.A 1880 -20 °C to 250 °C 250 °C to 1000 °C +/- 2°C or +/- 2% Emissivity, environment temperature, target distance, relative humidity -20 °C to 50 °C - 40 °C to 70 °C 20 %HR to 90 %HR – IP 54 Time, unity, language RayCAm offer Measurements tools: thermogram analysis RayCAm C.A 1885 Meas. spot Detection temp. Analisis area 4 moveable Alert Isotherm RayCAm C.A 1881 1 moveable Ajustable area Omplete thermogram +/- 2°C or +/- 2% Emissivity, environment temperature, distance to the target, relative humidity Sound / Visual None Posting mono color of a temperature range RayCAm preview Obtaining.jpeg picture RayCAm PC_F Physicsreport Line - 51 Realization of surveys Personnel et confidentiel RayCAm C.A 1880 Auto detection of the Max / Min temperature Precision Measurements correction RayCAm C.A 1883 None RayCAm offer Caractéristiques générales RayCAm C.A 1885 RayCAm C.A 1883 RayCAm C.A 1881 Laser 635 nm (red) class II, 1 mW Alimentation SONY battery 7,2V Autonomy: 2heures Programmable deactivation Interfaces Weight Delivered state PC_F Physics Line - 52 Personnel et confidentiel RayCAm C.A 1880 Electrical: USB, Video (PAL / NTSC) Mecanical: tripod < 700 g 1 camera + lens, Software USB, video connexion 2 batteries + 1 loader Tripod adaptator, Sun-shield User’s manual, test report 1 camera + lens, Software USB, video connexion 1 batterie + 1 loader User’s manual, test report RayCAm, inspection report The report is an integral part of a maintenance programme and Vital complement to taking thermograms Aim: - Reference database - Planning of work - Complementary inspection after repair => Requires on-site parameter reading PC_F Physics Line - 53 Personnel et confidentiel RayCAm report analysis software Easy to use PC_F Physics Line - 54 Personnel et confidentiel Personalized reports in all simplicity Many tools present helping at the creation of your report Cursor Thermogram insertion Picture, logo insertion Text area insertion Insertion of a temperature profile With its table Result table insertion Link between a tool and a thermogram PC_F Physics Line - 55 Personnel et confidentiel Personalized reports in all simplicity Multitude of tools for a complete thermogramanalysis To delete an analysis tool PC_F Physics Line - 56 Personnel et confidentiel Personalized reports in all simplicity Modify the parameters of the thermogram at will! With each analysis tool, its parameters: associate different emissivities to each point added on your thermogram Your analysis becomes relevant and in conformity with reality PC_F Physics Line - 57 Personnel et confidentiel Reports Highlights all the elements necessary for the correct interpretation of the phenomenon Distribution to department(s) concerned Handling of problem analysed Implementation of corrective actions Diffusion within the company For a better communicatio n within your company, record it under Word PC_F Physics Line - 58 Personnel et confidentiel Conclusion… RayCAm forms integral part of a complete inspection program Properly implemented and maintained, it has a direct impact on the quality of the products and the production RayCAm “envisages” the breakdowns… … CHAUVIN ARNOUX answers to all your requirements with the whole of its range PC_F Physics Line - 59 Personnel et confidentiel